{"id":20894,"date":"2024-09-11T13:32:12","date_gmt":"2024-09-11T11:32:12","guid":{"rendered":"https:\/\/www.lampert.info\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/"},"modified":"2025-11-24T15:56:53","modified_gmt":"2025-11-24T14:56:53","slug":"welding-dental-crowns-with-laser-bonding-elements","status":"publish","type":"tutorial","link":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/","title":{"rendered":"Welding dental crowns with laser bonding elements"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"20894\" class=\"elementor elementor-20894 elementor-19493\" data-elementor-post-type=\"tutorial\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-59c4b9d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"59c4b9d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c172e39\" data-id=\"c172e39\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8d4eadf elementor-widget elementor-widget-heading\" data-id=\"8d4eadf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Welding telescopic\/double crowns with laser connection elements<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01c0409 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"01c0409\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f7c4c0 elementor-widget elementor-widget-text-editor\" data-id=\"8f7c4c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">This section deals with the welded connection of separate secondary crowns with a cast partial framework.<\/p><p style=\"text-align: center;\"> <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c053a2b elementor-widget elementor-widget-spacer\" data-id=\"c053a2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-a44a22c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a44a22c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-449d41e\" data-id=\"449d41e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-inner-section elementor-element elementor-element-f245dee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f245dee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-209a727\" data-id=\"209a727\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f3b9544 elementor-widget elementor-widget-text-editor\" data-id=\"f3b9544\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In the past, cast partial bases on telescopic crowns were usually modeled directly approximally or orally flat in classical dental technology if a subsequent soldered connection was planned. Even in the casting technique, this solution proved to be extremely unsuitable for a welded connection. <\/p>\n<p>On the one hand, it is almost impossible to produce a distortion-free welded joint with a good fit in this way. The bigger problem, however, is the long-term stability of the joint. <br>With this type of design, all <img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-19496 alignright\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png\" alt=\"\" width=\"300\" height=\"180\" srcset=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png 300w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-1024x615.png 1024w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-768x462.png 768w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-1536x923.png 1536w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1.png 1905w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> forces occurring would always be transferred directly into the welded joint, which would greatly increase the likelihood of the joint breaking due to fatigue and result in costly repairs downstream. <\/p>\n<p>Regardless of whether a hybrid telescopic prosthesis is to be cast, fabricated using CAD\/CAM techniques or a combination of the two, care must be taken during the planning stage to ensure that the masticatory forces are transferred to the construction and that the welding merely ensures a stable, positive connection between the components. This is the classic type of shear distributor. <\/p>\n<p>Only a few design options are shown schematically below; there are certainly other conceivable alternatives. These can be constructed individually, from ready-made wax parts or possibly from a database, depending on the tools available. <\/p>\n<p>The dimensioning of the connectors should be as delicate as possible in accordance with the available space and individual circumstances (e.g. bruxism), but absolutely as stable as necessary. <img decoding=\"async\" class=\"wp-image-19499 alignright\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-300x108.png\" alt=\"\" width=\"417\" height=\"150\" srcset=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-300x108.png 300w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-1024x368.png 1024w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-768x276.png 768w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-1536x552.png 1536w, https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-2-2048x736.png 2048w\" sizes=\"(max-width: 417px) 100vw, 417px\" \/><br>Common to all variants is the need for the tertiary construction to fit the secondary parts as precisely as possible in order to avoid possible distortions during welding right from the start (e.g. through clearance fit in contrast to preparation for an adhesive connection, where a small gap for the adhesive is absolutely necessary), as well as design-related tilting moments that could affect the subsequent weld seam.&nbsp; &nbsp;<\/p>\n<p>When welding, one telescope at a time should be completely welded, not several at the same time. This gives you better control over the fit of the work on the model. <\/p>\n<p>It is advisable to select lower welding parameters for the first welding points. These are only intended for fixing the components and should be set from both the occlusal and basal sides. <\/p>\n<p>The parameters can then be increased. <u>Only a guideline value<\/u> could be a connection of a secondary crown made of a high gold alloy with a CoCr cast partial:<\/p>\n<p>Material CoCr-&gt;Au &#8211; Power 40 % &#8211; Pulse duration 7 ms &#8211; <img decoding=\"async\" class=\"alignnone size-full wp-image-19437\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/Schweissgeometrie-2.png\" alt=\"\" width=\"71\" height=\"50\"> or also <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-19502\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/Schweissgeometrie-3.png\" alt=\"\" width=\"61\" height=\"47\"><\/p>\n<p>It is advisable not to weld a continuous weld seam from one side at a time, but to place the welding points individually, always alternating diagonally opposite each other, until the seam is complete. This procedure allows any stresses that may arise to be compensated for directly. The work is always placed back on the model to check that it fits correctly so that any necessary corrective action can be taken. <x id=\"gid_0\"><\/x>If necessary, certain areas can also be reinforced with laser welding wire. No major finishing of the welded work is necessary.   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"featured_media":0,"parent":0,"menu_order":0,"template":"","class_list":["post-20894","tutorial","type-tutorial","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Welding dental crowns with laser bonding elements - Lampert Precision Welding<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Welding dental crowns with laser bonding elements - Lampert Precision Welding\" \/>\n<meta property=\"og:description\" content=\"Welding telescopic\/double crowns with laser connection elements This section deals with the welded connection of separate secondary crowns with a cast partial framework. In the past, cast partial bases on [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/\" \/>\n<meta property=\"og:site_name\" content=\"Lampert Precision Welding\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-24T14:56:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1905\" \/>\n\t<meta property=\"og:image:height\" content=\"1145\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/\",\"url\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/\",\"name\":\"Welding dental crowns with laser bonding elements - Lampert Precision Welding\",\"isPartOf\":{\"@id\":\"https:\/\/www.lampert.info\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png\",\"datePublished\":\"2024-09-11T11:32:12+00:00\",\"dateModified\":\"2025-11-24T14:56:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage\",\"url\":\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png\",\"contentUrl\":\"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.lampert.info\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Welding dental crowns with laser bonding elements\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.lampert.info\/en\/#website\",\"url\":\"https:\/\/www.lampert.info\/en\/\",\"name\":\"Lampert Precision Welding\",\"description\":\"Innovative Feinschwei\u00dftechnik\",\"publisher\":{\"@id\":\"https:\/\/www.lampert.info\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.lampert.info\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.lampert.info\/en\/#organization\",\"name\":\"Lampert Precision Welding\",\"url\":\"https:\/\/www.lampert.info\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png\",\"contentUrl\":\"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png\",\"width\":642,\"height\":196,\"caption\":\"Lampert Precision Welding\"},\"image\":{\"@id\":\"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Welding dental crowns with laser bonding elements - Lampert Precision Welding","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/","og_locale":"en_US","og_type":"article","og_title":"Welding dental crowns with laser bonding elements - Lampert Precision Welding","og_description":"Welding telescopic\/double crowns with laser connection elements This section deals with the welded connection of separate secondary crowns with a cast partial framework. In the past, cast partial bases on [&hellip;]","og_url":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/","og_site_name":"Lampert Precision Welding","article_modified_time":"2025-11-24T14:56:53+00:00","og_image":[{"width":1905,"height":1145,"url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/","url":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/","name":"Welding dental crowns with laser bonding elements - Lampert Precision Welding","isPartOf":{"@id":"https:\/\/www.lampert.info\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage"},"image":{"@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png","datePublished":"2024-09-11T11:32:12+00:00","dateModified":"2025-11-24T14:56:53+00:00","breadcrumb":{"@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#primaryimage","url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png","contentUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2024\/09\/doppelkrone-1-300x180.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.lampert.info\/en\/tutorials\/welding-dental-crowns-with-laser-bonding-elements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.lampert.info\/en\/"},{"@type":"ListItem","position":2,"name":"Welding dental crowns with laser bonding elements"}]},{"@type":"WebSite","@id":"https:\/\/www.lampert.info\/en\/#website","url":"https:\/\/www.lampert.info\/en\/","name":"Lampert Precision Welding","description":"Innovative Feinschwei\u00dftechnik","publisher":{"@id":"https:\/\/www.lampert.info\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lampert.info\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.lampert.info\/en\/#organization","name":"Lampert Precision Welding","url":"https:\/\/www.lampert.info\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png","contentUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png","width":642,"height":196,"caption":"Lampert Precision Welding"},"image":{"@id":"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/tutorial\/20894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/tutorial"}],"about":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/types\/tutorial"}],"version-history":[{"count":5,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/tutorial\/20894\/revisions"}],"predecessor-version":[{"id":27369,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/tutorial\/20894\/revisions\/27369"}],"wp:attachment":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/media?parent=20894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}