{"id":30476,"date":"2026-06-15T16:50:24","date_gmt":"2026-06-15T14:50:24","guid":{"rendered":"https:\/\/www.lampert.info\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/"},"modified":"2026-06-25T16:12:26","modified_gmt":"2026-06-25T14:12:26","slug":"welding-platinum-capsules-hermetic-seals-in-the-laboratory","status":"publish","type":"post","link":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/","title":{"rendered":"Welding Platinum Capsules: Hermetic Seals in the Laboratory"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"30476\" class=\"elementor elementor-30476 elementor-30387\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-8b8685b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8b8685b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8ad114c\" data-id=\"8ad114c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1c92a7c elementor-widget elementor-widget-heading\" data-id=\"1c92a7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Welding Platinum Capsules: Hermetic Seals in the Laboratory<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fac43e3 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"fac43e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be4400f elementor-widget elementor-widget-text-editor\" data-id=\"be4400f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hermetically sealing a platinum capsule means joining a thin-walled precious-metal shell in a gas-tight manner without altering the sample inside. In the laboratory, the actual experiment is often contained within: a mineral sample for high-pressure petrology, a reference standard for trace element analysis, or a substance sensitive to air. Three properties are critical for the seal: <strong>seam tightness<\/strong>, <strong>minimal heat input<\/strong> to the capsule\u2019s contents, and <strong>reproducible seam quality<\/strong> across the batch. Micro-TIG welding with the Lampert Micro Arc Welder (MAW) delivers all three, even for wall thicknesses in the tenths-of-a-millimeter range.   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-1cf2e09\" data-id=\"1cf2e09\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5235c33 elementor-widget elementor-widget-image\" data-id=\"5235c33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-5c34d7c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5c34d7c\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-855af2d\" data-id=\"855af2d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-66eac7d elementor-widget elementor-widget-heading\" data-id=\"66eac7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Is There Platinum in the Lab?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33f2594 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"33f2594\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-781ca53 elementor-widget elementor-widget-text-editor\" data-id=\"781ca53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In the laboratory, platinum is not a material used for jewelry, but rather a functional material. This is due to two properties that work together: platinum is <strong>chemically inert<\/strong> and can withstand <strong>high temperatures<\/strong>. It resists mineral acids, air, and water under normal conditions and hardly reacts with the enclosed sample material even under high pressure and high temperature (source: Britannica, \u201cnoble metal,\u201d accessed June 15, 2026). Thus, the capsule wall does not distort the experiment.   <\/p><p>The melting point of pure platinum is approximately <strong>1,768 \u00b0C<\/strong> (Source: Britannica \/ Biology Insights, accessed June 15, 2026), significantly higher than that of gold (about 1,064 \u00b0C) or silver. For welding, this means that platinum requires more energy than the softer precious metals, but remains very weldable. In the Lampert material classification system, platinum is considered very weldable, with a note to use higher settings due to its higher melting point.  <\/p><p>Typical laboratory capsules have thin walls, often with a wall thickness of 0.1 to 0.3 mm. This is precisely where the sealing process becomes critical: The seam must be airtight without burning through the wall and without allowing heat to reach the sample. The pulse duration, measured in milliseconds, is the key factor here.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-a599520 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a599520\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-380c27c\" data-id=\"380c27c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d92dcd elementor-widget elementor-widget-heading\" data-id=\"2d92dcd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Typical Applications for Platinum Capsules<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24b21f2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"24b21f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08ae87a elementor-widget elementor-widget-text-editor\" data-id=\"08ae87a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Platinum capsules are used wherever a sample needs to be enclosed under conditions that other materials cannot withstand or that would compromise the sample:<\/p><ul><li><strong>High-pressure research capsules.<\/strong>  Platinum and platinum-rhodium capsules for diamond anvil cell experiments and high-pressure experimental petrology. A platinum shell is welded to a platinum lid, forming a chemically impermeable seal before the sample is subjected to pressure (Source: SERC Carleton; Wikipedia \u201cDiamond anvil cell,\u201d accessed June 15, 2026). <\/li><li><strong>Reference and standard capsules<\/strong> for isotopic, neutron activation, and trace element analysis, in which a standard or sample is hermetically sealed.<\/li><li><strong>Encapsulation in glove box atmospheres.<\/strong>  Seal substances that are sensitive to air or moisture in platinum capsules under an inert gas atmosphere.<\/li><li><strong>Thermocouple junctions.<\/strong>  Pt\/Pt-Rh thermocouples (Types S and R) are a well-established micro-TIG application and share the same material properties as the capsules.<\/li><\/ul><p>The manufacturing process in the lab differs from industrial-scale production: The focus is not on output per hour, but on achieving a reproducible, verifiably tight seam on each individual part.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-5004498\" data-id=\"5004498\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0714647 elementor-widget elementor-widget-image\" data-id=\"0714647\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"540\" src=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-mikroimpulsschweissen-lichtbogen-1024x691.png\" class=\"attachment-large size-large wp-image-30102\" alt=\"Platinum capsule during micropulse welding with the Lampert Micro Arc Welder, arc ignition\" srcset=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-mikroimpulsschweissen-lichtbogen-1024x691.png 1024w, https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-mikroimpulsschweissen-lichtbogen-300x202.png 300w, https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-mikroimpulsschweissen-lichtbogen-768x518.png 768w, https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-mikroimpulsschweissen-lichtbogen.png 1238w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-d749b6d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d749b6d\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-457e212\" data-id=\"457e212\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8f3b4a1 elementor-widget elementor-widget-heading\" data-id=\"8f3b4a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Materials Used in the Platinum Capsule<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ed45e7 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8ed45e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0a2420 elementor-widget elementor-widget-text-editor\" data-id=\"b0a2420\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Platinum is rarely used alone. In practice, platinum capsules are combined with related precious metals and functional materials. The following overview lists the materials that can be hermetically joined using MAW:  <\/p><table><thead><tr><th>Material<\/th><th>Typical Applications<\/th><th>Weldability<\/th><\/tr><\/thead><tbody><tr><td><strong>Platinum (Pt)<\/strong><\/td><td>High-pressure capsules, reference capsules, crucible joints<\/td><td>Very good; higher energy than gold\/silver due to melting point<\/td><\/tr><tr><td><strong>Platinum-Rhodium (Pt-Rh)<\/strong><\/td><td>Diamond-stamped cells, Pt\/Pt-Rh thermocouples<\/td><td>Very good, thin wall thicknesses<\/td><\/tr><tr><td><strong>Gold \/ Palladium<\/strong><\/td><td>Softer capsules, lower pressure\/temperature levels<\/td><td>Very good, lower energy than platinum<\/td><\/tr><tr><td><strong>Stainless steel 1.4404 \/ 316L<\/strong><\/td><td>Sample capsules, sensor and pressure transducer housings<\/td><td>Very good, biocompatible<\/td><\/tr><tr><td><strong>Grade 2 \/ Grade 5 Titanium<\/strong><\/td><td>Corrosion-critical lab capsules, implantable housings<\/td><td>Very good; very good inert gas coverage required<\/td><\/tr><tr><td><strong>Tantalum \/ Niobium \/ Zirconium<\/strong><\/td><td>Specialized and corrosion-critical encapsulation for laboratory use<\/td><td>Subject to conditions; test welding recommended<\/td><\/tr><\/tbody><\/table><p>The complete methodology and classification of materials within the cluster: <a href=\"https:\/\/www.lampert.info\/en\/hermetic-sealing-with-micro-TIG-welding\/\">Hermetic Sealing with Micro-TIG Welding<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-f9b6e6c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f9b6e6c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8dda3b9\" data-id=\"8dda3b9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9dc3fa5 elementor-widget elementor-widget-heading\" data-id=\"9dc3fa5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Micro-TIG Welding for Platinum Capsules<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc22aa elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"0bc22aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40801e5 elementor-widget elementor-widget-text-editor\" data-id=\"40801e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Minimal heat input to the capsule contents.<\/strong>  Pulse durations ranging from 0.1 to 34 milliseconds concentrate the heat on the seam. The capsule wall absorbs the energy, while the contents are virtually unaffected. For air-sensitive substances, mineral samples, and prepared standards, this is the difference between a usable sample and a compromised one.  <\/li><li><strong>Energy range for thin walls and a higher melting point.<\/strong>  With a peak current range of 5 to 1,200 A, the MAW covers both the low energy required for 0.1-mm walls and the higher energy needed for platinum due to its melting point.<\/li><li><strong>A purely metallurgical compound.<\/strong>  No flux, no soldering limit, no contamination pathways. This is important for laboratory applications involving isotopic or chemical analysis, where any foreign substance can interfere with the results. <\/li><li><strong>Reproducibility thanks to pre-installed welding curves.<\/strong>  The MAW comes with a dedicated platinum program (one of the twelve preinstalled material programs). Parameters are documented, and processes can be repeated via the batch. <\/li><li><strong>Glove-box compatible.<\/strong>  With the proper preparation, the MAW operates in an inert gas atmosphere for encapsulation of components sensitive to air or moisture.<\/li><li><strong>Suitable for helium leak testing.<\/strong>  When prepared properly, the seam consistently meets the hermeticity specifications typical for the application. For high-pressure research capsules, typical acceptance leak rates range between 10\u207b\u2076 and 10\u207b\u2078 mbar\u00b7l\/s. <\/li><\/ul><p>The <a href=\"https:\/\/www.lampert.info\/?p=30369\">\u201cHelium Leak Test: A Practical Guide to Hermetic Welds\u201d<\/a> discusses how to qualify a weld.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-5c2cac2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5c2cac2\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ec5488c\" data-id=\"ec5488c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e6b75c2 elementor-widget elementor-widget-heading\" data-id=\"e6b75c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Practical Recommendations for Welding Thin-Walled Platinum Capsules<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec40204 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"ec40204\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8585345 elementor-widget elementor-widget-text-editor\" data-id=\"8585345\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Preparation<\/h3><ul><li><strong>Thoroughly pre-clean the workpiece.<\/strong>  Ultrasonic cleaning is the laboratory standard. Contaminants in pores or crevices burn during welding and cause porosity in the weld. <\/li><li><strong>Check the joint geometry.<\/strong>  A weld seam only seals parts that are geometrically aligned. A clean fit between the lid and the rim of the capsule is essential for a tight seam. <\/li><li><strong>Add the contents before closing the container.<\/strong>  Sequence: Insert the sample, then seal the capsule. The minimal heat input ensures a reliable process. <\/li><\/ul><h3>Welding parameters<\/h3><ul><li><strong>Low to medium energy plus a sharp tungsten electrode<\/strong> for thin capsule walls. Practical starting point for wall thicknesses of 0.1 to 0.3 mm: 15 to 25% energy, 0.5 to 1.5 ms pulse duration; then fine-tune on the test piece. Due to its higher melting point, platinum tends to fall at the upper end of this range.  <\/li><li><strong>Inert gas:<\/strong> Argon \u2265 99.9% (Argon 4.6), optimal flow rate approx. 2 l\/min with automatic pre- and post-flow.<\/li><li><strong>For contents that are highly sensitive to heat<\/strong>, also consider using thermal masking or a heat sink mount.<\/li><\/ul><h3>Validation<\/h3><ul><li><strong>Visual inspection under a microscope.<\/strong>  A clean, oxide-free weld with no pores. Platinum oxidizes very little; however, a dull or grainy weld indicates that the energy is too high or that the inert gas is insufficient. <\/li><li><strong>Helium leak test<\/strong> after welding, depending on the geometry and target leak rate. Determine the target value before designing the weld. <\/li><li><strong>Cross-section of initial samples.<\/strong>  Document the penetration depth and seam quality before starting production.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-db4c227 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"db4c227\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c652e31\" data-id=\"c652e31\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a09816 elementor-widget elementor-widget-heading\" data-id=\"7a09816\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Device recommendation: the Lampert Micro Arc Welder<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a62b42a elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"a62b42a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c9574b elementor-widget elementor-widget-text-editor\" data-id=\"2c9574b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><thead><tr><th>Specification<\/th><th>Value<\/th><\/tr><\/thead><tbody><tr><td>Peak current (TIG)<\/td><td>5-1.200 A<\/td><\/tr><tr><td>Pulse duration<\/td><td>0.1-34 ms<\/td><\/tr><tr><td>Minimum workpiece thickness<\/td><td>0.1 mm<\/td><\/tr><tr><td>Spot weld diameter<\/td><td>0.2-4.0 mm; &gt;1 mm penetration with 1.3 mm electrode<\/td><\/tr><tr><td>Material programs (pre-installed)<\/td><td>12 (universal, gold, silver, platinum, palladium, bronze, stainless steel, titanium, aluminum, tin, brass, copper)<\/td><\/tr><tr><td>Patented welding process control<\/td><td>Yes (real-time fault detection)<\/td><\/tr><tr><td>Industry 4.0 interface<\/td><td>Modbus TCP\/IP via LAN (21 documented registers)<\/td><\/tr><tr><td>Inert gas<\/td><td>Argon \u2265 99.9 %; approx. 2 l\/min<\/td><\/tr><tr><td>Weight<\/td><td>10.9 kg<\/td><\/tr><tr><td>EU certification<\/td><td>EN 60974-6, EN 61000-6-2\/-6-4, RoHS 2011\/65\/EU; UKCA-compliant<\/td><\/tr><tr><td>Guarantee<\/td><td>3 years, manufactured and serviced in Germany<\/td><\/tr><tr><td>Investment (complete entry)<\/td><td>from approx. 7,000 EUR net<\/td><\/tr><tr><td>Training<\/td><td>One-day workshop in Werneck (own workpieces welcome)<\/td><\/tr><\/tbody><\/table><p>Full product specification: <a href=\"https:\/\/www.lampert.info\/en\/products\/industry\/microarcwelder\/\">Lampert Micro Arc Welder product page<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-fda9f28 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fda9f28\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f0938f5\" data-id=\"f0938f5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8c2db76 elementor-widget elementor-widget-heading\" data-id=\"8c2db76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Frequently Asked Questions About Welding Platinum Capsules<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09710e6 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"09710e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0e4663 elementor-widget elementor-widget-eael-adv-accordion\" data-id=\"e0e4663\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-adv-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t            <div class=\"eael-adv-accordion\" id=\"eael-adv-accordion-e0e4663\" data-scroll-on-click=\"no\" data-scroll-speed=\"300\" data-accordion-id=\"e0e4663\" data-accordion-type=\"accordion\" data-toogle-speed=\"300\">\n            <div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"is-platinum-even-easy-to-weld\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"1\" aria-controls=\"elementor-tab-content-2351\"><span class=\"eael-accordion-tab-title\">Is platinum even easy to weld?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2351\" class=\"eael-accordion-content clearfix\" data-tab=\"1\" aria-labelledby=\"is-platinum-even-easy-to-weld\"><p>Yes. Platinum is considered very weldable. Because of its higher melting point of about 1,768 \u00b0C (Source: Britannica \/ Biology Insights, accessed June 15, 2026), higher settings are required than for gold or silver, but the process remains the same. Platinum-rhodium alloys behave similarly.   <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"how-can-i-prevent-the-thin-capsule-wall-from-burning-through\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"2\" aria-controls=\"elementor-tab-content-2352\"><span class=\"eael-accordion-tab-title\">How can I prevent the thin capsule wall from burning through?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2352\" class=\"eael-accordion-content clearfix\" data-tab=\"2\" aria-labelledby=\"how-can-i-prevent-the-thin-capsule-wall-from-burning-through\"><p>Using low energy and short pulse durations. Practical starting point for wall thicknesses of 0.1 to 0.3 mm: 15 to 25% energy, 0.5 to 1.5 ms pulse duration, with a sharply ground tungsten electrode. Resharpen on the test piece and inspect the initial sample in a cross-section.  <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"is-the-contents-of-the-capsule-protected-during-welding\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"3\" aria-controls=\"elementor-tab-content-2353\"><span class=\"eael-accordion-tab-title\">Is the contents of the capsule protected during welding?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2353\" class=\"eael-accordion-content clearfix\" data-tab=\"3\" aria-labelledby=\"is-the-contents-of-the-capsule-protected-during-welding\"><p>Yes. The pulse duration, measured in milliseconds, keeps the heat at the seam. The capsule wall absorbs the energy, while the contents remain at nearly ambient temperature. That is precisely why the sample is inserted before the capsule is sealed and then welded shut.   <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"can-i-seal-platinum-capsules-for-high-pressure-research\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"4\" aria-controls=\"elementor-tab-content-2354\"><span class=\"eael-accordion-tab-title\">Can I seal platinum capsules for high-pressure research?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2354\" class=\"eael-accordion-content clearfix\" data-tab=\"4\" aria-labelledby=\"can-i-seal-platinum-capsules-for-high-pressure-research\"><p>Yes. Platinum and platinum-rhodium capsules are a well-established application for diamond anvil cell experiments and high-pressure experimental petrology. Platinum is preferred in these applications due to its chemical inertness under high pressure and high temperature (Source: SERC Carleton; Wikipedia \u201cDiamond anvil cell,\u201d accessed June 15, 2026).  <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"is-a-helium-leak-test-possible-after-welding\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"5\" aria-controls=\"elementor-tab-content-2355\"><span class=\"eael-accordion-tab-title\">Is a helium leak test possible after welding?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2355\" class=\"eael-accordion-content clearfix\" data-tab=\"5\" aria-labelledby=\"is-a-helium-leak-test-possible-after-welding\"><p>Yes, depending on the geometry and the target leak rate. For high-pressure research capsules, typical acceptance leak rates range from 10\u207b\u2076 to 10\u207b\u2078 mbar\u00b7l\/s. The Helium Leak Test Guide describes how to perform the test. For very tight specifications, validate prototype samples in advance.   <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"can-you-weld-inside-the-glove-box-too\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"6\" aria-controls=\"elementor-tab-content-2356\"><span class=\"eael-accordion-tab-title\">Can you weld inside the glove box, too?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2356\" class=\"eael-accordion-content clearfix\" data-tab=\"6\" aria-labelledby=\"can-you-weld-inside-the-glove-box-too\"><p>Yes, with the proper preparation. The MAW operates in inert gas atmospheres, which is important for encapsulation of samples that are sensitive to air or moisture. If you fill the sample directly with the target gas during sealing, you encapsulate the sample in a defined atmosphere.  <\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"which-inert-gas-and-which-flow-rate\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"7\" aria-controls=\"elementor-tab-content-2357\"><span class=\"eael-accordion-tab-title\">Which inert gas and which flow rate?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2357\" class=\"eael-accordion-content clearfix\" data-tab=\"7\" aria-labelledby=\"which-inert-gas-and-which-flow-rate\"><p>Argon \u2265 99.9 % (argon 4.6), optimum flow rate approx. 2 l\/min with automatic upstream and downstream flow directly at the device.<\/p>\n<\/div>\n\t\t\t\t\t<\/div><div class=\"eael-accordion-list\">\n\t\t\t\t\t<div id=\"who-can-advise-me-on-my-specific-platinum-capsule-assignment\" class=\"elementor-tab-title eael-accordion-header\" tabindex=\"0\" data-tab=\"8\" aria-controls=\"elementor-tab-content-2358\"><span class=\"eael-accordion-tab-title\">Who can advise me on my specific Platinum Capsule assignment?<\/span><i aria-hidden=\"true\" class=\"fa-toggle fas fa-plus\"><\/i><\/div><div id=\"elementor-tab-content-2358\" class=\"eael-accordion-content clearfix\" data-tab=\"8\" aria-labelledby=\"who-can-advise-me-on-my-specific-platinum-capsule-assignment\"><p>The Lampert Application Team at <a href=\"mailto:mail@lampert.info\">mail@lampert.info<\/a>. A free sample weld with a written welding report is available. This is particularly worthwhile for platinum capsules, as wall thickness, geometry, and target leak rates vary significantly.  <\/p>\n<\/div>\n\t\t\t\t\t<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-7070590 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7070590\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-61f8dc2\" data-id=\"61f8dc2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a5be879 elementor-widget elementor-widget-heading\" data-id=\"a5be879\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion: When Micro-TIG Welding Is the Right Choice for Platinum Capsules<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2046adc elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"2046adc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7351a51 elementor-widget elementor-widget-text-editor\" data-id=\"7351a51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When it comes to platinum capsules in the lab, it\u2019s not throughput that matters, but rather a tight, reproducible weld on the individual part without damaging the sample. The Lampert Micro Arc Welder delivers exactly that: an energy range that accommodates both thin walls and platinum\u2019s higher melting point, heat input that protects the sample, a dedicated platinum program for repeatable results, and a pure metallurgical weld without flux. The investment threshold of around 7,000 EUR for a complete benchtop workstation aligns with the reality of laboratory work, where individual parts and small batches are in demand, not mass production.  <\/p><p>Anyone who needs to qualify the seal should plan for the helium leak test right from the start and set the target leak rate before designing the weld. For context regarding materials and methodology within the broader picture, see the <a href=\"https:\/\/www.lampert.info\/en\/hermetic-sealing-with-micro-TIG-welding\/\">\u201cHermetic Sealing\u201d<\/a> and <a href=\"https:\/\/www.lampert.info\/?p=30369\">\u201cHelium Leak Test\u201d<\/a> cluster pillars. <\/p><p>For test welds and application-specific advice, the Lampert application team is happy to receive inquiries at <a href=\"mailto:mail@lampert.info\">mail@lampert.info<\/a>. A written welding report is enclosed with every test weld. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Platinum capsules are hermetically sealed without altering the sample. Micro-pulse welding with the Lampert Micro Arc Welder produces tight seams, minimal heat input, and reproducible results on thin-walled laboratory and high-pressure research capsules. <\/p>\n","protected":false},"author":13,"featured_media":30363,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_focuskw":"Welding Platinum Capsules","_yoast_wpseo_title":"Welding Platinum Capsules: Hermetic Sealing","_yoast_wpseo_metadesc":"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_canonical":"","inline_featured_image":false,"_elementor_version":"4.0.2","_elementor_pro_version":"","_lampert_jsonld":"","_lampert_source":"","_wp_page_template":"default","_lampert_origin":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-30476","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-unkategorisiert"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Welding Platinum Capsules: Hermetic Sealing<\/title>\n<meta name=\"description\" content=\"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Welding Platinum Capsules: Hermetic Sealing\" \/>\n<meta property=\"og:description\" content=\"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/\" \/>\n<meta property=\"og:site_name\" content=\"Lampert Precision Welding\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-15T14:50:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-25T14:12:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sebastian Beck\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sebastian Beck\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/\"},\"author\":{\"name\":\"Sebastian Beck\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#\\\/schema\\\/person\\\/a7975fbeb35708e7faf00cf3cf7d51b6\"},\"headline\":\"Welding Platinum Capsules: Hermetic Seals in the Laboratory\",\"datePublished\":\"2026-06-15T14:50:24+00:00\",\"dateModified\":\"2026-06-25T14:12:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/\"},\"wordCount\":1798,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\",\"articleSection\":[\"Unkategorisiert\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/\",\"url\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/\",\"name\":\"Welding Platinum Capsules: Hermetic Sealing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\",\"datePublished\":\"2026-06-15T14:50:24+00:00\",\"dateModified\":\"2026-06-25T14:12:26+00:00\",\"description\":\"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg\",\"width\":2560,\"height\":1707,\"caption\":\"Gas-tight, welded platinum capsule, prepared for the helium leak test\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/homepage\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Welding Platinum Capsules: Hermetic Seals in the Laboratory\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/\",\"name\":\"Lampert Precision Welding\",\"description\":\"Innovative Feinschwei\u00dftechnik\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#organization\",\"name\":\"Lampert Precision Welding\",\"url\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/logo_lampert.png\",\"contentUrl\":\"https:\\\/\\\/www.lampert.info\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/logo_lampert.png\",\"width\":642,\"height\":196,\"caption\":\"Lampert Precision Welding\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/#\\\/schema\\\/person\\\/a7975fbeb35708e7faf00cf3cf7d51b6\",\"name\":\"Sebastian Beck\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g\",\"caption\":\"Sebastian Beck\"},\"sameAs\":[\"http:\\\/\\\/www.lampert.info\"],\"url\":\"https:\\\/\\\/www.lampert.info\\\/en\\\/author\\\/sebastian-beck\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Welding Platinum Capsules: Hermetic Sealing","description":"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/","og_locale":"en_US","og_type":"article","og_title":"Welding Platinum Capsules: Hermetic Sealing","og_description":"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.","og_url":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/","og_site_name":"Lampert Precision Welding","article_published_time":"2026-06-15T14:50:24+00:00","article_modified_time":"2026-06-25T14:12:26+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg","type":"image\/jpeg"}],"author":"Sebastian Beck","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sebastian Beck","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#article","isPartOf":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/"},"author":{"name":"Sebastian Beck","@id":"https:\/\/www.lampert.info\/en\/#\/schema\/person\/a7975fbeb35708e7faf00cf3cf7d51b6"},"headline":"Welding Platinum Capsules: Hermetic Seals in the Laboratory","datePublished":"2026-06-15T14:50:24+00:00","dateModified":"2026-06-25T14:12:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/"},"wordCount":1798,"publisher":{"@id":"https:\/\/www.lampert.info\/en\/#organization"},"image":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg","articleSection":["Unkategorisiert"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/","url":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/","name":"Welding Platinum Capsules: Hermetic Sealing","isPartOf":{"@id":"https:\/\/www.lampert.info\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#primaryimage"},"image":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg","datePublished":"2026-06-15T14:50:24+00:00","dateModified":"2026-06-25T14:12:26+00:00","description":"Hermetically seal platinum capsules without altering the sample. Micro-TIG welding with the Lampert Micro Arc Welder: a tight seam with minimal heat.","breadcrumb":{"@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#primaryimage","url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg","contentUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2026\/06\/platinkapsel-gasdicht-verschweisst-lecktest-scaled.jpg","width":2560,"height":1707,"caption":"Gas-tight, welded platinum capsule, prepared for the helium leak test"},{"@type":"BreadcrumbList","@id":"https:\/\/www.lampert.info\/en\/welding-platinum-capsules-hermetic-seals-in-the-laboratory\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.lampert.info\/en\/homepage\/"},{"@type":"ListItem","position":2,"name":"Welding Platinum Capsules: Hermetic Seals in the Laboratory"}]},{"@type":"WebSite","@id":"https:\/\/www.lampert.info\/en\/#website","url":"https:\/\/www.lampert.info\/en\/","name":"Lampert Precision Welding","description":"Innovative Feinschwei\u00dftechnik","publisher":{"@id":"https:\/\/www.lampert.info\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lampert.info\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.lampert.info\/en\/#organization","name":"Lampert Precision Welding","url":"https:\/\/www.lampert.info\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png","contentUrl":"https:\/\/www.lampert.info\/wp-content\/uploads\/2021\/12\/logo_lampert.png","width":642,"height":196,"caption":"Lampert Precision Welding"},"image":{"@id":"https:\/\/www.lampert.info\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lampert.info\/en\/#\/schema\/person\/a7975fbeb35708e7faf00cf3cf7d51b6","name":"Sebastian Beck","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9c6fc82d9de40693d591d72c25373d291376e7dcfc1be59f3c549741105afc16?s=96&d=mm&r=g","caption":"Sebastian Beck"},"sameAs":["http:\/\/www.lampert.info"],"url":"https:\/\/www.lampert.info\/en\/author\/sebastian-beck\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/posts\/30476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/comments?post=30476"}],"version-history":[{"count":1,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/posts\/30476\/revisions"}],"predecessor-version":[{"id":30477,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/posts\/30476\/revisions\/30477"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/media\/30363"}],"wp:attachment":[{"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/media?parent=30476"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/categories?post=30476"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lampert.info\/en\/wp-json\/wp\/v2\/tags?post=30476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}